GPULoom

Dell PowerEdge R470

Simple, Scalable and Efficient solutions

The 1U, one-socket PowerEdge R470 is tailored to help you reach your budgetary requirements with optimized power and balanced performance in your data center.

Category: Brand:
Processor

• One Intel® Xeon® 6 E-core processor with up to 144 cores
• One Intel® Xeon® 6 P-core processor with up to 86 cores with R1S option

Memory

• 16 DDR5 DIMM slot, supports RDIMM 4 TB max, speeds up to 6400 MT/s
• Intel® Xeon® 6 E-core processor – supports 1 TB max
• Intel® Xeon® 6 P-core processor with up to 86 cores with R1S option – supports 4 TB max
• Supports registered ECC DDR5 DIMMs only
Note: The installed processor may reduce the operating speed of the DIMM

Storage controllers

• Internal Controllers (RAID): PERC H365i DC- MHS, front PERC H965i DC-MHS, PERC H365i adapter, PERC H965i adapter
• External Controllers: HBA465e, H965e(RAID)
• Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1 DC-MHS): HWRAID 1, 2 xM.2 NVMe SSDs, M.2 interposer with upto 2 x M.2 NVMe SSDs or USB

Drive Bays

Front bays:
• Up to 8 x EDSFF E3.S Gen5 NVMe max 491.52 TB
• Up to 16 x EDSFF E3.S Gen5 NVMe max 983.04 TB
• Up to 8 x 2.5-inch SATA/ NVMe max 491.52 TB
• Up to 10 x 2.5 – inch SATA/ NVMe (with 4 x 2.5 -inch universal) max 614.4 TB
• Up to 4 x 3.5 – inch SATA max 128 TB* (only supported with rear 2 x E3.S drives; not supported as standalone front-only configuration)
Rear bays:
• Up to 2 x EDSFF E3.S Gen5 NVMe max 122.88 TB

Power Supplies

• 800 W Platinum/ Titanium 100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W Platinum/ Titanium 100-240 VAC or 240 HVDC, hot swap redundant
• 1500 W Titanium 100-240 VAC or 240 HVDC, hot swap redundant
• 1500 W 277 Vac and HVDC Titanium, hot swap redundant*
• 1400 W -48v DC Titanium, hot swap redundant
• 1800 W Titanium 100-240 VAC or 240 HVDC, hot swap redundant*

Cooling Options

Air cooling

Fans

• Up to 4 sets (dual fan module) hot swappable fan

Dimensions

• Height – 42.8 mm (1.69 inches)
• Width – 482 mm (19.0 inches)
• Depth – 816.92 mm (32.16 inches) with bezel
• Depth – 815.14 mm (32.09 inches) without bezel
• Depth (Front I/O Configuration) — 829.44 mm (32.09 inches) without bezel
Note: Front I/O configuration will not have a bezel.

Form Factor

1U rack server

Embedded Management

• iDRAC
• iDRAC Direct
• iDRAC RESTfull API with redfish
• RACADM CLI
• iDRAC Service Module

Bezel

Optional security bezel

OpenManage Software

• OpenManage Enterprise (OME)
• OME Power Manager
• OME Services
• OME Update Manager
• OME APEX AIOps Observability
• OME Integration for VMware vCenter (with VMware Aria Operations)
• OME integration for Microsoft System Center
• OpenManage Integration for Windows Admin Center

Tools

IPMI

Integrations and Connections

OpenManage Integrations
• Redhat Ansible Collections
• Terraform Providers

Change Management

• Dell Repository Manager
• Dell System Update
• Enterprise Catalogs
• Server Update Utility (SUU)*

Security

• Cryptographically signed firmware
• Data at Rest Encryption (SEDs with local or external key mgmt)
• Secure Boot
• Secured Component Verification (Hardware integrity check)
• Secure Erase
• Silicon Root of Trust
• System Lockdown (requires iDRAC10 Enterprise or Datacenter)
• TPM 2.0 FIPS, CC-TCG certified
• Chassis Intrusion Detection

OCP network options

• Up to two OCP NIC card 3.0: Two slots on the front or two slots on the rear (optional) Slot 2: 1 x16 OCP 3.0 Slot 5: 1 x16 OCP 3.0 Slot 31: 1 x16 OCP 3.0 Slot 32: 1 x16 OCP 3.0

BOSS

Slot 34: 1 x4 BOSS Slot 3: 1 x4 BOSS

Embedded NIC

1 Gb dedicated BMC Ethernet port

PCIe Add-in Card (AIC) NIC

NA

GPU Options

Up to 4 x 75 W SW

DPU Options

NVIDIA BlueField-3 2×200 GbE B3220

Ports

Front Ports
• 1 x USB 2.0 Type – C port
• 1 x USB 2.0 Type A port (optional)
• 1 x Mini-DisplayPort (optional)
• 1 x DB9 Serial (with front I/O configuration)
• 1 x Dedicated BMC Ethernet port (with front I/O configuration)
Rear Ports
• 1 x Dedicated BMC Ethernet port
• 2 x USB 3.1 Type A ports
• 1 x VGA
Internal Ports
• 1 x USB 3.1 Type A port

PCIe slots

Up to 4 Gen5 PCIe slots (x16 connectors)
• Slot 1: 1 x8 Gen5 Low Profile
• Slot 1:1 x16 Gen5 (x16 connector) full height, half length on rear riser
• Slot 4: 1 x16 Gen5 (x16 connector) full height, half length on rear riser
• Slot 31: 1 x16 Gen5 (x16 connector) full height, half length on rear riser
• Slot 32: 1 x16 Gen5 (x16 connector) full height, half length on rear riser

Gen5 PCIe slots

4

Operating System and Hypervisors

• Canonical Ubuntu Server LTS
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• VMware ESXi
• Windows Server
• Windows Server Datacenter
For specifications and interoperability details, see Dell.com/OSsupport.

OEM-ready version available

From bezel to BIOS to packaging, your servers can look and feel as if they were designed and built by you. For more information, visit Dell. com/OEM.

Dell PowerEdge R470 Overview

Dell PowerEdge R470 is designed for buyers planning a configured enterprise infrastructure deployment. Simple, Scalable and Efficient solutions The 1U, one-socket PowerEdge R470 is tailored to help you reach your budgetary requirements with optimized power and balanced performance in your data center. GPULoom supplies quotation-based configurations for data-center, cloud, virtualization and business application projects. Because processor, memory, storage, networking, risers, power supplies, firmware, warranty and condition can vary by unit, the exact bill of materials is confirmed before an order or project commitment.

Dell PowerEdge R470 Configuration Highlights

  • Processor platform: • One Intel® Xeon® 6 E-core processor with up to 144 cores • One Intel® Xeon® 6 P-core processor with up to 86 cores with R1S option
  • Memory: • 16 DDR5 DIMM slot, supports RDIMM 4 TB max, speeds up to 6400 MT/s • Intel® Xeon® 6 E-core processor – supports 1 TB max • Intel® Xeon® 6 P-core processor with up to 86 cores with R1S option – supports 4 TB max • Suppo…
  • Storage options: Front bays: • Up to 8 x EDSFF E3.S Gen5 NVMe max 491.52 TB • Up to 16 x EDSFF E3.S Gen5 NVMe max 983.04 TB • Up to 8 x 2.5-inch SATA/ NVMe max 491.52 TB • Up to 10 x 2.5 – inch SATA/ NVMe (with 4 x 2.5 -inch universal) m…
  • Expansion: Up to 4 Gen5 PCIe slots (x16 connectors) • Slot 1: 1 x8 Gen5 Low Profile • Slot 1:1 x16 Gen5 (x16 connector) full height, half length on rear riser • Slot 4: 1 x16 Gen5 (x16 connector) full height, half length on rear ri…
  • Accelerator options: Up to 4 x 75 W SW
  • Form factor: 1U rack server

These capabilities describe the platform and its supported configuration range rather than a guaranteed stock configuration. Buyers should provide the expected workload, required capacity, preferred drive layout, network speed, operating environment and redundancy goals. GPULoom will then confirm compatibility and availability for the requested build.

Processor and Memory Planning

For Dell PowerEdge R470, the available processor information is: • One Intel® Xeon® 6 E-core processor with up to 144 cores • One Intel® Xeon® 6 P-core processor with up to 86 cores with R1S option. CPU choice should be evaluated against application licensing, core count, clock requirements, virtualization density and power limits. A higher core count is not automatically the best choice for every workload, particularly where software licensing or per-core performance affects total cost.

The documented memory information is: • 16 DDR5 DIMM slot, supports RDIMM 4 TB max, speeds up to 6400 MT/s • Intel® Xeon® 6 E-core processor – supports 1 TB max • Intel® Xeon® 6 P-core processor with up to 86 cores with R1S option – supports 4 TB max • Supports registered ECC DDR5 DIMMs only Note: The installed proce…. Final memory planning should account for capacity, channel population, module type, rank, speed and future expansion. For clustered or virtualized environments, it is also useful to reserve headroom for failover, maintenance and workload growth rather than sizing only for the initial deployment.

Storage, Networking and Expansion

Storage planning for Dell PowerEdge R470 should start from the required balance of capacity, latency, endurance and serviceability. The current platform data lists: Front bays: • Up to 8 x EDSFF E3.S Gen5 NVMe max 491.52 TB • Up to 16 x EDSFF E3.S Gen5 NVMe max 983.04 TB • Up to 8 x 2.5-inch SATA/ NVMe max 491.52 TB • Up to 10 x 2.5 – inch SATA/ NVMe (with 4 x 2.5 -inch universal) max 614.4 TB • Up to 4 x 3.5 – inch SATA max 128 TB* (only supported with rear 2…. Drive-bay support does not by itself guarantee that every backplane, controller, cable, boot device or RAID combination is included, so these items are verified as part of the quotation.

Networking and PCIe requirements should be specified alongside storage because adapters, risers and accelerator choices can compete for slots, lanes, power and cooling capacity. Include required Ethernet speeds, port counts, optics or transceivers, host bus adapters, storage controllers and accelerator models in the request. GPULoom will confirm that the proposed combination fits the selected chassis and power envelope.

Workloads and Deployment Fit

The listed workload positioning includes virtualization, business applications, data services and other enterprise infrastructure workloads selected according to the final configuration. Actual suitability depends on the complete configuration, software stack and performance target. Before choosing a server, compare compute density, memory footprint, local storage, network throughput, rack space, acoustic and thermal limits, and the operational model used by the data center.

This product can be considered for new deployments, capacity expansion, standardized server refreshes and compatible replacement projects. For an existing environment, share the current server model, operating system or hypervisor, storage topology, network design and any application constraints. That information helps reduce configuration risk and makes the quotation more useful.

Management, Security and Lifecycle Considerations

Management planning should cover remote access, monitoring, alerting, firmware baselines and integration with existing administration tools. Available platform information includes: • iDRAC • iDRAC Direct • iDRAC RESTfull API with redfish • RACADM CLI • iDRAC Service Module. Licensing and feature availability can differ by configuration, so required management capabilities should be named explicitly.

Security planning should include: • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) • Secure Erase • Silicon Root of Trust • System Lockdown (require…. Buyers should also define requirements for secure boot, trusted platform modules, drive sanitization, firmware versions, account access, asset records and data-at-rest protection. Warranty coverage, service level, included rails, bezels, power cords and other accessories must be confirmed in the final quotation.

Request a Configured Dell PowerEdge R470 Quote

Use the GPULoom server catalog to compare related systems, or contact GPULoom with the desired processor, memory, storage, networking, accelerator, warranty and delivery destination. Inventory, condition, lead time and included components are confirmed before purchase. For additional platform documentation, consult the official Dell Support portal.

Dell PowerEdge R470 FAQ

Can GPULoom configure Dell PowerEdge R470 for my workload?

Yes. Send the workload, operating system or hypervisor, CPU and memory targets, storage layout, network requirements and delivery country. GPULoom will confirm a compatible configuration and current availability.

Are the listed maximum specifications included?

No. Maximum or supported specifications describe platform capability. The installed processor, memory, drives, controllers, adapters, power supplies, licenses and accessories are confirmed in the quotation.

Can I request specific drives, RAID, NICs or accelerators?

Yes, subject to platform compatibility and inventory. Provide exact part numbers when possible, or describe the required capacity, endurance, interface, port speed and workload.

What should I confirm before ordering?

Confirm the complete bill of materials, condition, warranty, firmware, rails and bezel, power cords, licenses, lead time, shipping terms and destination requirements.

Scroll to Top