| Interfaces | 32 x 40/100GE + 8 x 400GE; *For centralized storage scenarios only |
|---|---|
| Switching Capacity | 16Tbps |
| Packet Forwarding Rate | 3840Mpps |
| Power Consumption | Typical power consumption:; • 456W (100% load, 16*100G+4*400G ports with copper cables, room temperature, dual AC power supplies); • 473W (100% load, 8*100G+8*200G+4*400G ports with copper cables, room temperature, dual AC power supplies); • 536W (100% load, 16*100G+4*400G ports with short-reach optical modules, room temperature, dual AC power supplies); • 558W (100% load, 8*100G+8*200G+4*400G ports with short-reach optical modules, room temperature, dual AC power supplies); Maximum power consumption:; • 676W (100% load, 32*100G+8*400G ports with short-reach optical modules, room temperature, dual AC power supplies); • 719W (100% load, 16*100G+16*200G+8*400G ports with short-reach optical modules, room temperature, dual AC power supplies); • 933W (100% load, 32*100G+8*400G ports with long-reach optical modules, high temperature, dual AC power supplies); • 1020W (100% load, 16*100G+16*200G+8*400G ports with long-reach optical modules, high temperature, dual AC power supplies) |
| Buffer | 72MB |
| Security | Granular micro-segmentation security isolation (IPv4 and IPv6); MACsec |
| Reliability | LACP; Hardware BFD (minimum packet interval 3ms); VRRP; M-LAG; DPFR; MoFRR; DPCF |
| Intelligent O&M | Telemetry; NetStream; sFlow; Enhanced SPAN/RSPAN/ERSPAN; IFIT; Packet Event root cause analysis |
| Data Center Features | 1588v2; RoCE V1/V2; VXLAN routing and bridging; BGP-EVPN; PFC, AI ECN; PFC deadlock prevention; iNOF; NPCC (Network-based Proactive Congestion Control); ECN Overlay |
| Power Supply Method | 1200W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-65Hz; DC: 190V DC to 290V DC;; 1200W DC power module: -48V DC to -60V DC; +48V DC; 2000W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-66Hz; DC: 190V DC to 290V DC; 2000W HVDC power module: 260V DC to 400V DC |
| Power Redundancy | 1+1 backup |
CE8855H-SAN-40F
32 x 40/100GE + 8 x 400GE 16Tbps. RFQ — quotation on request.
Overview
The CE8855H-SAN-40F is an enterprise data-center Ethernet switch with 32 x 40/100GE + 8 x 400GE; *For centralized storage scenarios only, 16Tbps switching capacity and 3840Mpps of packet forwarding. It is intended for enterprise and data-center network deployments.
At a glance
- Interfaces: 32 x 40/100GE + 8 x 400GE; *For centralized storage scenarios only
- Switching Capacity: 16Tbps
- Packet Forwarding Rate: 3840Mpps
- Power Consumption: Typical power consumption:; 456W (100% load, 16*100G+4*400G ports with copper cables, room temperature, dual AC power supplies); 473W (100% load, 8*100G+8*200G+4*400G ports with copper cables, room temperature, dual AC power supplies); 536W (100% load, 16*100G+4*400G ports with short-reach optical modules, room temperature, dual AC power supplies); 558W (100% load, 8*100G+8*200G+4*400G ports with short-reach optical modules, room temperature,…
- Buffer: 72MB
- Security: Granular micro-segmentation security isolation (IPv4 and IPv6); MACsec
- Reliability: LACP; Hardware BFD (minimum packet interval 3ms); VRRP; M-LAG; DPFR; MoFRR; DPCF
- Intelligent O&M: Telemetry; NetStream; sFlow; Enhanced SPAN/RSPAN/ERSPAN; IFIT; Packet Event root cause analysis
- Data Center Features: 1588v2; RoCE V1/V2; VXLAN routing and bridging; BGP-EVPN; PFC, AI ECN; PFC deadlock prevention; iNOF; NPCC (Network-based Proactive Congestion Control); ECN Overlay
- Power Supply Method: 1200W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-65Hz; DC: 190V DC to 290V DC; 1200W DC power module: -48V DC to -60V DC; +48V DC; 2000W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-66Hz; DC: 190V DC to 290V DC; 2000W HVDC power module: 260V DC to 400V DC
- Power Redundancy: 1+1 backup
When to choose this data-center Ethernet switch
Choose this data-center Ethernet switch where the deployment needs 32 x 40/100GE + 8 x 400GE; *For centralized storage scenarios only with 16Tbps of capacity and 1200W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-65Hz;… power, plus Granular micro-segmentation security isolation (IPv4 and IPv6); MACsec.
Platform & compatibility
Supports interfaces 32 x 40/100GE + 8 x 400GE; *For centralized storage scenarios only, features 1588v2; RoCE V1/V2; VXLAN routing and bridging; BGP-EVPN; PFC, AI ECN; PFC deadlock prevention; iNOF; NPCC (Network-based…, power 1200W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-65Hz; DC: 190V DC to 290V…, buffer 72MB. Confirm the software version, optics/transceivers and power options for your network before ordering.
Deployment notes
The CE8855H-SAN-40F is supplied as configured hardware; software version and optics are selected at order time. power: 1200W AC & 240V DC power module: AC: 90V AC to 290V AC, 45Hz-65Hz; DC: 190V DC…. consumption: Typical power consumption:; 456W (100% load,…. buffer: 72MB. Send the required port mix, software licences and optics for a firm configuration and quote.
FAQ
What interfaces does it have? 32 x 40/100GE + 8 x 400GE; *For centralized storage scenarios only.
What is its capacity? 16Tbps.
What is the packet forwarding rate? 3840Mpps.
What security features does it include? Granular micro-segmentation security isolation (IPv4 and IPv6); MACsec.
How do I get pricing? Send the required configuration; quotes depend on quantity, software and destination.
Related
Configuration, availability and lead time depend on the required quantity, software version and delivery destination. Send your requirement to receive a quotation.