| Product SKU | DB730S |
|---|---|
| Ports | 128 ports (96x 64G SFP+ plus 16x 2x64G SFP-DD), supporting E_Port, F_Port, M_Port and D_Port |
| Optics | 64G Fibre Channel hot-pluggable SFP-DD and SN connectors, 64Gb/s SWL |
| Power Supply | Dual, hot-swappable, redundant power supplies with integral cooling fans and status LEDs. 80 Plus Gold. |
| Rack Mounting | Rack-mount rail kits included |
| System Architecture | System Architecture |
| Fibre Channel Ports | 128 ports (96 64G SFP+ ports, plus 16 2x64G SFP-DD ports), each supporting E_Ports, F_Ports, M_Ports, D_Ports, and EX_Ports. |
| Scalability | Full-fabric architecture with a maximum of 239 switches |
| Certified Maximum | 4K active nodes; 56 switches, 19 hops in Brocade Fabric OS® fabrics |
| Performance | Non-blocking architecture with wire-speed forwarding of traffic: |
| Traffic Load Balancing | Frame-based trunking with up to eight SFP+ ports per ISL trunk; up to 512Gb/s per ISL trunk. |
| Aggregate Bandwidth | 8.192Tb/s |
| Maximum Fabric Latency | Latency for locally switched ports is 460 ns (including FEC). |
| Maximum Frame Size | 2112-byte payload |
| Frame Buffers | 2K per switching ASIC |
| Classes Of Service | Class 2, Class 3, Class F (inter-switch frames) |
| Port Types | • D_Port (ClearLink® Diagnostic Port), E_Port, EX_Port, F_Port, M_Port |
| Data Traffic Types | Fabric switches supporting unicast |
| Media Types | • 64G: Brocade Secure hot-pluggable SFP-DD, SN connector; 64 Gb/s SWL. |
| USB Port | One standard USB port for firmware download, SupportSave, and configuration upload or download. |
| Fabric Services | BB Credit Recovery; Brocade Advanced Zoning (Default Zoning, Port/WWN Zoning, Peer Zoning); Congestion Signaling; Dynamic Fabric Provisioning (DFP); Dynamic Path Selection (DPS); Extended Fabrics; Fabric Performance Impact Notification (FPIN); Fabric Vision; FDMI; Flow Vision; F_Port Trunking; FSPF; Integrated Routing; ISL Trunking; Management Server; Name Server; NPIV; NTP v3; Port Decommission/Fencing; QoS; Registered State Change Notification (RSCN); Slow Drain Device Quarantine (SDDQ); Target-Driven Zoning; Traffic Optimizer; Virtual Fabrics (Logical Switch, Logical Fabric); VMID+ and AppServer. |
| Extension | Integrated optional 10G Fibre Channel for DWDM MAN connectivity |
| Management | Management |
| Security | DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; Port Binding; RADIUS; TACACS+; user-defined Role-Based Access Control (RBAC); Secure Boot; Secure Copy (SCP); Secure Syslog; SFTP; SSH v2; SSL; Switch Binding; Trusted Switch; Trusted FOS Certificates (TruFOS); root access removed. |
| Diagnostics | Active Support Connectivity (ASC) and Brocade Support Link (BSL); built-in flow generator; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; Fabric Performance Impact Monitoring (FPI); flow mirroring; Forward Error Correction (FEC); frame viewer; Global Quiet Time (GQT); IO Insight for SCSI and NVMe monitoring; Monitoring and Alerting Policy Suite (MAPS); nondisruptive daemon restart; optics health monitoring; POST and embedded online/ offline diagnostics, including environmental monitoring, FCping, and Pathinfo (FC traceroute); power monitoring; RAStrace logging; Rolling Reboot Detection (RRD); Syslog/Audit Log; VM Insight. |
| Mechanical | Mechanical |
| Enclosure | • Front-to-back airflow; non-port-side exhaust; power from back, 2U |
| Support | Support |
| Warranty | Three-year customer-replaceable unit limited warranty with 9×5 next business day parts delivered. Three-year software/firmware entitlement. |
| Power | Dual, hot-swappable, redundant power supplies with integral cooling fans and status LEDs. 80 Plus Gold. |
Lenovo ThinkSystem DB730S FC SAN Switch
The Lenovo ThinkSystem DB730S FC SAN Switch is a storage network switch from Lenovo, supporting 128 ports.
Overview
The Lenovo ThinkSystem DB730S FC SAN Switch is an enterprise network device. It is intended for enterprise and data-center network deployments.
At a glance
- Product SKU: DB730S
- Ports: 128 ports (96x 64G SFP+ plus 16x 2x64G SFP-DD), supporting E_Port, F_Port, M_Port and D_Port
- Optics: 64G Fibre Channel hot-pluggable SFP-DD and SN connectors, 64Gb/s SWL
- Power Supply: Dual, hot-swappable, redundant power supplies with integral cooling fans and status LEDs. 80 Plus Gold.
- Rack Mounting: Rack-mount rail kits included
- System Architecture: System Architecture
- Fibre Channel Ports: 128 ports (96 64G SFP+ ports, plus 16 2x64G SFP-DD ports), each supporting E_Ports, F_Ports, M_Ports, D_Ports, and EX_Ports. 48-port base configuration; additional ports are enabled with two 24-port SFP+ PODs (Ports on Demand), plus a 32-port SFP-DD POD (16 2x64G SFP-DD transceivers), scaling the switch from 48 ports to 128 ports. The SFP+ ports are capable of auto-negotiating to 8, 16, 32, or 64G speeds depending on the SFP+ model and the…
- Scalability: Full-fabric architecture with a maximum of 239 switches
- Certified Maximum: 4K active nodes; 56 switches, 19 hops in Brocade Fabric OS® fabrics
- Performance: Non-blocking architecture with wire-speed forwarding of traffic:; 8GFC: 8.5 Gb/s line speed, full duplex; 10GFC: 10.53 Gb/s line speed, full duplex; 10Gb/s optionally programmable to fixed port speed.; 16GFC: 14.025 Gb/s line speed, full duplex; 32GFC: 28.05 Gb/s line speed, full duplex; 64GFC: 57.8 Gb/s line speed, full duplex
- Traffic Load Balancing: Frame-based trunking with up to eight SFP+ ports per ISL trunk; up to 512Gb/s per ISL trunk. Exchange based load balancing across ISLs with Dynamic Path Selection (DPS) included in Brocade Fabric OS
- Aggregate Bandwidth: 8.192Tb/s
- Maximum Fabric Latency: Latency for locally switched ports is 460 ns (including FEC).
- Maximum Frame Size: 2112-byte payload
- Frame Buffers: 2K per switching ASIC
- Classes Of Service: Class 2, Class 3, Class F (inter-switch frames)
- Port Types: D_Port (ClearLink® Diagnostic Port), E_Port, EX_Port, F_Port, M_Port; Optional port-type control
- Data Traffic Types: Fabric switches supporting unicast
- Media Types: 64G: Brocade Secure hot-pluggable SFP-DD, SN connector; 64 Gb/s SWL.; 64G: Brocade Secure hot-pluggable SFP+, LC connector; 64 Gb/s SWL, LWL 10 km.; 32G: Brocade Secure hot-pluggable SFP+, LC connector; 32 Gb/s SWL, LWL 10 km, ELWL 25 km.; 10G: Brocade Secure hot-pluggable SFP+, LC connector; 10 Gb/s SWL, LWL 10 km. Fibre Channel distance is subject to fiber-optic cable and port speed.
- USB Port: One standard USB port for firmware download, SupportSave, and configuration upload or download.
- Fabric Services: BB Credit Recovery; Brocade Advanced Zoning (Default Zoning, Port/WWN Zoning, Peer Zoning); Congestion Signaling; Dynamic Fabric Provisioning (DFP); Dynamic Path Selection (DPS); Extended Fabrics; Fabric Performance Impact Notification (FPIN); Fabric Vision; FDMI; Flow Vision; F_Port Trunking; FSPF; Integrated Routing; ISL Trunking; Management Server; Name Server; NPIV; NTP v3; Port Decommission/Fencing; QoS; Registered State Change Notification…
- Extension: Integrated optional 10G Fibre Channel for DWDM MAN connectivity
- Management: Management Brocade Advanced Web Tools; Brocade SANnav Management Portal and SANnav Global View; Command Line Interface (CLI); EZSwitchSetup; HTTP/HTTPS; RESTful API; SNMP v1/v3 (FE MIB, FC Management MIB); SSH. 10/100/1000Mb/s Ethernet (RJ-45) port, serial console port, and USB port.
- Security: DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; Port Binding; RADIUS; TACACS+; user-defined Role-Based Access Control (RBAC); Secure Boot; Secure Copy (SCP); Secure Syslog; SFTP; SSH v2; SSL; Switch Binding; Trusted Switch; Trusted FOS Certificates (TruFOS); root access removed.
- Diagnostics: Active Support Connectivity (ASC) and Brocade Support Link (BSL); built-in flow generator; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; Fabric Performance Impact Monitoring (FPI); flow mirroring; Forward Error Correction (FEC); frame viewer; Global Quiet Time (GQT); IO Insight for SCSI and NVMe monitoring; Monitoring and Alerting Policy Suite (MAPS); nondisruptive daemon restart;…
- Mechanical: Mechanical
- Enclosure: Front-to-back airflow; non-port-side exhaust; power from back, 2U; Back-to-front airflow; non-port-side intake; power from back, 2U
- Support: Support
- Warranty: Three-year customer-replaceable unit limited warranty with 9×5 next business day parts delivered. Three-year software/firmware entitlement.
- Power: Dual, hot-swappable, redundant power supplies with integral cooling fans and status LEDs. 80 Plus Gold.
When to choose this network device
Choose this network device where the deployment needs the listed interface mix, plus DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS;….
Platform & compatibility
Supplied as a complete network platform. Confirm the software version, optics/transceivers and power options for your network before ordering.
Deployment notes
The Lenovo ThinkSystem DB730S FC SAN Switch is supplied as configured hardware; software version and optics are selected at order time. Send the required port mix, software licences and optics for a firm configuration and quote.
FAQ
What security features does it include? DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; Port Binding; RADIUS; TACACS+; user-defined Role-Based Access Control (RBAC);….
How do I get pricing? Send the required configuration; quotes depend on quantity, software and destination.
Related
Configuration, availability and lead time depend on the required quantity, software version and delivery destination. Send your requirement to receive a quotation.














