FusionServer 2158H V8

FusionServer 2158H V8 is a 2U single-socket rack server powered by a 4th Gen AMD EPYC™ 9004 (Genoa) or 5th-Gen AMD EPYC™ 9005 series (Turin) processor with up to 500 W TDP.The FusionServer 2158H V8 is a next-generation 2U1P rack server designed to meet the demands of virtualization, big data analytics, databases, cloud scenarios, and AI inference.With outstanding performance, strong scalability, proven reliability, and ease of management and deployment, the 2158H V8 is ideal for handling complex workloads in industries such as Internet and telecom.

SKU: XFUSION-FUSIONSERVER-2158H-V8 Category: Brand:
Form Factor

2U rack server

Processor

1 x 4th Gen AMD EPYC™ 9004 (Genoa) or 5th-Gen AMD EPYC™ 9005 series (Turin) processor with up to 500 W TDP per processor

Local Storage

– 8 x 2.5″ SAS/SATA/NVMe drives
– 8 x 3.5″ SAS/SATA/NVMe drives
– 12 x 3.5″ SAS/SATA/NVMe drives
– 24 x 2.5″ drives (16 x NVMe drives + 8 x SAS/SATA drives)
– 2 x M.2 SSDs (SAS/SATA)

RAID

RAID 0, 1, 10, 5, 50, 6, and 60; supercapacitor for cache data protection against power failures; RAID level migration, drive roaming, self-diagnosis, and remote web-based configuration

Network

2 x OCP 3.0 NICs, which can be configured as required; support hot swap and PCIe 5.0

PCle Expansion

10 x PCIe expansion slots; support PCIe 5.0

GPU Card

4 x dual-width GPU cards and 1 x dual-width DPU card

Fan

Four 80 x 80 or six 60 x 60 hot-swappable counter-rotating fan modules in N+1 redundancy

PSU

– 2 x PSUs in 1+1 redundancy:
– 900 W/1500 W/2000 W Platinum AC PSUs
– 900 W/2000 W/3000 W Titanium AC PSUs
– 1200 W -48 V DC PSUs
– 1500 W 380 V high-voltage DC PSUs

Management

– The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic O&M, and hardware security hardening.
– The iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/VNC KVM, and supports out-of-band management functions such as monitoring, diagnosis, configuration, Agentless, and remote control for simplified management.
– It is optional to configure the FusionDirector management software that provides advanced management features such as five intelligent technologies, enabling intelligent, automatic, visualized, and refined management throughout the lifecycle.

OS

xFusion FusionOS, Microsoft Windows Server, SUSE Linux Enterprise Server, VMware vSphere, Red Hat Enterprise Linux, Oracle, and Ubuntu

Security

Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, security panel, secure boot, and chassis cover opening detection

Operating Temperature

5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A1 to A4

Certification

CE, UL, CCC, FCC, VCCI, and RoHS

Installation Suite

L-shaped, adjustable, and holding rails

Dimensions (H x W x D)

86.1 mm x 447 mm x 798 mm (3.39 in. x 17.60 in. x 31.42 in.)

Overview

The FusionServer 2158H V8 is an enterprise server in a 2U chassis, configured for virtualisation, databases and general enterprise workloads. Its processor, memory, storage, networking and expansion options are summarised below.

At a glance

  • Form Factor: 2U rack server
  • Processor: 1 x 4th Gen AMD EPYC™ 9004 (Genoa) or 5th-Gen AMD EPYC™ 9005 series (Turin) processor with up to 500 W TDP per processor
  • Local Storage: – 8 x 2.5″ SAS/SATA/NVMe drives – 8 x 3.5″ SAS/SATA/NVMe drives – 12 x 3.5″ SAS/SATA/NVMe drives – 24 x 2.5″ drives (16 x NVMe drives + 8 x SAS/SATA drives) – 2 x M.2 SSDs (SAS/SATA)
  • RAID: RAID 0, 1, 10, 5, 50, 6, and 60; supercapacitor for cache data protection against power failures; RAID level migration, drive roaming, self-diagnosis, and remote web-based configuration
  • Network: 2 x OCP 3.0 NICs, which can be configured as required; support hot swap and PCIe 5.0
  • PCle Expansion: 10 x PCIe expansion slots; support PCIe 5.0
  • GPU Card: 4 x dual-width GPU cards and 1 x dual-width DPU card
  • Fan: Four 80 x 80 or six 60 x 60 hot-swappable counter-rotating fan modules in N+1 redundancy
  • PSU: – 2 x PSUs in 1+1 redundancy: – 900 W/1500 W/2000 W Platinum AC PSUs – 900 W/2000 W/3000 W Titanium AC PSUs – 1200 W -48 V DC PSUs – 1500 W 380 V high-voltage DC PSUs
  • Management: – The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic O&M, and hardware security hardening. – The iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/VNC KVM, and supports out-of-band management functions such as monitoring, diagnosis, configuration, Agentless, and remote control for simplified management. – It is optional to configure the FusionDirector management software that provides advanced management features such as five…
  • OS: xFusion FusionOS, Microsoft Windows Server, SUSE Linux Enterprise Server, VMware vSphere, Red Hat Enterprise Linux, Oracle, and Ubuntu
  • Security: Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, security panel, secure boot, and chassis cover opening detection
  • Operating Temperature: 5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A1 to A4
  • Certification: CE, UL, CCC, FCC, VCCI, and RoHS
  • Installation Suite: L-shaped, adjustable, and holding rails
  • Dimensions (H x W x D): 86.1 mm x 447 mm x 798 mm (3.39 in. x 17.60 in. x 31.42 in.)

When to choose this server

Choose this platform where the deployment needs virtualisation, databases and general enterprise workloads. It uses a 2U chassis and – 2 x PSUs in 1+1 redundancy: – 900 W/1500 W/2000 W Platinum AC PSUs – 900… power; local storage options include – 8 x 2.5″ SAS/SATA/NVMe drives – 8 x 3.5″ SAS/SATA/NVMe drives – 12 x 3.5″ SAS/SATA/NVMe….

Platform & compatibility

Supports processors: 1 x 4th Gen AMD EPYC™ 9004 (Genoa) or 5th-Gen AMD EPYC™ 9005 series (Turin) processor with up to 500 W TDP per processor, network: 2 x OCP 3.0 NICs, which can be configured as required; support hot swap and PCIe 5.0, RAID: RAID 0, 1, 10, 5, 50, 6, and 60; supercapacitor for cache data protection…, OS: xFusion FusionOS, Microsoft Windows Server, SUSE Linux Enterprise Server, VMware vSphere, Red Hat Enterprise Linux,…. Confirm the CPU, memory, drive and PSU configuration, plus rack rails, against your workload and rack before ordering.

Deployment notes

The FusionServer 2158H V8 is supplied as a configured platform; CPU, memory, storage and PSU are chosen at order time. out-of-band management: – The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic…. power: – 2 x PSUs in 1+1 redundancy: – 900 W/1500 W/2000 W Platinum AC PSUs – 900 W/2000 W/3000…. network: 2 x OCP 3.0 NICs, which can be configured as required; support hot swap and PCIe 5.0. Rack rails, power distribution and cooling follow the 2U chassis class and are confirmed at order time. Send the required CPU, memory and drive mix for a firm configuration and quote.

FAQ

What processors does it support? 1 x 4th Gen AMD EPYC™ 9004 (Genoa) or 5th-Gen AMD EPYC™ 9005 series (Turin) processor with up to 500 W TDP per processor.

What drives does it accept? – 8 x 2.5″ SAS/SATA/NVMe drives – 8 x 3.5″ SAS/SATA/NVMe drives – 12 x 3.5″ SAS/SATA/NVMe drives – 24 x 2.5″ drives (16 x NVMe drives + 8 x SAS/SATA drives) – 2 x M.2 SSDs (SAS/SATA).

How is it managed? – The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic O&M, and hardware security hardening. – The iBMC….

How do I get pricing? Send the required configuration; quotes depend on quantity, options and delivery destination.

Related

Configuration, availability and lead time depend on the required quantity, server pairing and delivery destination. Send your requirement to receive a quotation.

Scroll to Top