FusionServer 2258H V7 (2258H V7) is a new-generation 2U 2-socket rack server designed for SDS, VDI, CDN, virtualization, big data, DB, cloud scenarios, AI inference, small enterprises, OA, and web applications, meeting requirements of enterprise or telecom service applications and other complex workloads. The 2258H V7 features low power consumption, solid scalability and reliability, easy deployment, and simplified management.

SKU: XFUSION-FUSIONSERVER-2258H-V7 Category: Brand:
Form Factor

2U rack server

Processor

1 or 2 x 4th Gen AMD EPYC™ 9004 Series processors (Genoa) with up to 400 W TDP per processor

Memory

12 or 24 x 4800 MT/s DDR5 DIMMs and 16 x DDR4/DDR5 DIMMs supported by CXL 1.1

Local Storage

– 8 x 2.5″ SAS/SATA drives
– 12 x 3.5″ SAS/SATA drives (including 4 x NVMe drives)
– Flash storage: 2 x M.2 SSDs (SATA/NVMe)

RAID

RAID 0, 1, 10, 5, 50, 6, and 60; supercapacitor for cache data protection against power failures; RAID level migration, drive roaming, self-diagnosis, and remote web-based configuration

Network

1 x OCP 3.0 NIC, which can be configured as required and supports hot swap and PCIe 5.0

PCle Expansion

1 x FlexIO slot dedicated for an OCP 3.0 NIC; up to 5 x full-height PCIe slots and 4 x dual-width PCIe 5.0 slots

GPU Card

4 x dual-width GPU cards

CXL Expansion

4 x CXL 1.1 cards, with memory expansion up to 16 x DDR5 DIMMs; up to 16 x DDR4 DIMMs*

Fan

4 x hot-swappable counter-rotating fan modules in N+1 redundancy

PSU

900 W Platinum/Titanium, 1500 W Platinum, 2000 W Platinum, or 3000 W Titanium hot-swappable power supplies, supporting 1+1 redundancy

Management

– The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic O&M, and hardware security hardening.
– The iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/VNC KVM, and supports out-of-band management functions such as monitoring, diagnosis, configuration, Agentless, and remote control for simplified management.
– It is optional to configure the FusionDirector management software that provides advanced management features such as five intelligent technologies, enabling intelligent, automatic, visualized, and refined management throughout the lifecycle.

OS

xFusion FusionOS, Microsoft Windows Server, SUSE Linux Enterprise Server, VMware vSphere, Red Hat Enterprise Linux, Oracle, and Ubuntu

Security

Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, security panel, secure boot, and chassis cover opening detection

Operating Temperature

5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A1 to A4

Certification

CE, NRTL, CCC, FCC, VCCI, and RoHS

Installation Suite

L-shaped, adjustable, and holding rails

Dimensions (H x W x D)

86.1 mm x 447 mm x 798 mm (3.39 in. x 17.60 in. x 31.42 in.)

Overview

The FusionServer 2258H V7 is an enterprise server in a 2U chassis, configured for virtualisation, databases and general enterprise workloads. Its processor, memory, storage, networking and expansion options are summarised below.

At a glance

  • Form Factor: 2U rack server
  • Processor: 1 or 2 x 4th Gen AMD EPYC™ 9004 Series processors (Genoa) with up to 400 W TDP per processor
  • Memory: 12 or 24 x 4800 MT/s DDR5 DIMMs and 16 x DDR4/DDR5 DIMMs supported by CXL 1.1
  • Local Storage: – 8 x 2.5″ SAS/SATA drives – 12 x 3.5″ SAS/SATA drives (including 4 x NVMe drives) – Flash storage: 2 x M.2 SSDs (SATA/NVMe)
  • RAID: RAID 0, 1, 10, 5, 50, 6, and 60; supercapacitor for cache data protection against power failures; RAID level migration, drive roaming, self-diagnosis, and remote web-based configuration
  • Network: 1 x OCP 3.0 NIC, which can be configured as required and supports hot swap and PCIe 5.0
  • PCle Expansion: 1 x FlexIO slot dedicated for an OCP 3.0 NIC; up to 5 x full-height PCIe slots and 4 x dual-width PCIe 5.0 slots
  • GPU Card: 4 x dual-width GPU cards
  • CXL Expansion: 4 x CXL 1.1 cards, with memory expansion up to 16 x DDR5 DIMMs; up to 16 x DDR4 DIMMs*
  • Fan: 4 x hot-swappable counter-rotating fan modules in N+1 redundancy
  • PSU: 900 W Platinum/Titanium, 1500 W Platinum, 2000 W Platinum, or 3000 W Titanium hot-swappable power supplies, supporting 1+1 redundancy
  • Management: – The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic O&M, and hardware security hardening. – The iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/VNC KVM, and supports out-of-band management functions such as monitoring, diagnosis, configuration, Agentless, and remote control for simplified management. – It is optional to configure the FusionDirector management software that provides advanced management features such as five…
  • OS: xFusion FusionOS, Microsoft Windows Server, SUSE Linux Enterprise Server, VMware vSphere, Red Hat Enterprise Linux, Oracle, and Ubuntu
  • Security: Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, security panel, secure boot, and chassis cover opening detection
  • Operating Temperature: 5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A1 to A4
  • Certification: CE, NRTL, CCC, FCC, VCCI, and RoHS
  • Installation Suite: L-shaped, adjustable, and holding rails
  • Dimensions (H x W x D): 86.1 mm x 447 mm x 798 mm (3.39 in. x 17.60 in. x 31.42 in.)

When to choose this server

Choose this platform where the deployment needs virtualisation, databases and general enterprise workloads. It uses a 2U chassis and 900 W Platinum/Titanium, 1500 W Platinum, 2000 W Platinum, or 3000 W Titanium… power; local storage options include – 8 x 2.5″ SAS/SATA drives – 12 x 3.5″ SAS/SATA drives (including 4 x NVMe drives) –….

Platform & compatibility

Supports processors: 1 or 2 x 4th Gen AMD EPYC™ 9004 Series processors (Genoa) with up to 400 W TDP per processor, memory: 12 or 24 x 4800 MT/s DDR5 DIMMs and 16 x DDR4/DDR5 DIMMs supported by CXL 1.1, network: 1 x OCP 3.0 NIC, which can be configured as required and supports hot swap and PCIe 5.0, RAID: RAID 0, 1, 10, 5, 50, 6, and 60; supercapacitor for cache data protection…, OS: xFusion FusionOS, Microsoft Windows Server, SUSE Linux Enterprise Server, VMware vSphere, Red Hat Enterprise Linux,…. Confirm the CPU, memory, drive and PSU configuration, plus rack rails, against your workload and rack before ordering.

Deployment notes

The FusionServer 2258H V7 is supplied as a configured platform; CPU, memory, storage and PSU are chosen at order time. out-of-band management: – The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic…. power: 900 W Platinum/Titanium, 1500 W Platinum, 2000 W Platinum, or 3000 W Titanium…. network: 1 x OCP 3.0 NIC, which can be configured as required and supports hot swap and PCIe 5.0. Rack rails, power distribution and cooling follow the 2U chassis class and are confirmed at order time. Send the required CPU, memory and drive mix for a firm configuration and quote.

FAQ

What processors does it support? 1 or 2 x 4th Gen AMD EPYC™ 9004 Series processors (Genoa) with up to 400 W TDP per processor.

What memory does it take? 12 or 24 x 4800 MT/s DDR5 DIMMs and 16 x DDR4/DDR5 DIMMs supported by CXL 1.1.

What drives does it accept? – 8 x 2.5″ SAS/SATA drives – 12 x 3.5″ SAS/SATA drives (including 4 x NVMe drives) – Flash storage: 2 x M.2 SSDs (SATA/NVMe).

How is it managed? – The iBMC chip integrates one dedicated management GE network port, providing comprehensive management features such as fault diagnosis, automatic O&M, and hardware security hardening. – The iBMC….

How do I get pricing? Send the required configuration; quotes depend on quantity, options and delivery destination.

Related

Configuration, availability and lead time depend on the required quantity, server pairing and delivery destination. Send your requirement to receive a quotation.

Scroll to Top