Inspur HF8000G6 High-End Storage

The Inspur HF8000G6 is a high-end enterprise storage system.

SKU: HF8000G6 Category: Brand:
Product SKU

HF8000G6

Processor

Multiple multi-core CPUs

Storage

SAS SSD, NVMe SSD

Storage Controller

RAID 0/1/10/5/6, InRAID 5/6

Power Supply

AC: 220 V, or 110 V dual live wire (220–264 V); DC: 240 V (240–320 V)

Hot-Swap Modules

Controllers, drives, power supplies, fans, BBU, FC cards, NVMe cards, RoCE cards, SAS cards, etc.

Security

Intelligent service assurance (InQoS), intelligent automatic cache partitioning (InAutoPartition)

Cache

256 GB/512 GB/1 TB/1.5 TB

Disk Enclosure

2U25-bay SAS expansion enclosure; 2U25-bay NVMe expansion enclosure; mixed use supported

Front-end Ports

48

Weight

Control enclosure: 38.5; JBOD: 23.8; JBOF: 23

Operating Temperature

At -60 m to +900 m: 5°C to 35°C. At 900 m to 3,000 m: reduce by 1°C for every 300 m of elevation gain

Storage Temperature

-40°C to 70°C (BBU excluded from the system); 0°C to 70°C recommended

Humidity

10% to 90% RH, non-condensing

Storage Humidity

10% to 93% RH, non-condensing

Product Code

HF8000G6-CGF (V6)

Overview

The Inspur HF8000G6 High-End Storage is an enterprise enterprise storage system with 256 GB/512 GB/1 TB/1.5 TB of cache. It is built for enterprise enterprise storage system workloads.

At a glance

  • Product SKU: HF8000G6
  • Processor: Multiple multi-core CPUs
  • Storage: SAS SSD, NVMe SSD
  • Storage Controller: RAID 0/1/10/5/6, InRAID 5/6
  • Power Supply: AC: 220 V, or 110 V dual live wire (220–264 V); DC: 240 V (240–320 V)
  • Hot-Swap Modules: Controllers, drives, power supplies, fans, BBU, FC cards, NVMe cards, RoCE cards, SAS cards, etc.
  • Security: Intelligent service assurance (InQoS), intelligent automatic cache partitioning (InAutoPartition)
  • Cache: 256 GB/512 GB/1 TB/1.5 TB
  • Disk Enclosure: 2U25-bay SAS expansion enclosure; 2U25-bay NVMe expansion enclosure; mixed use supported
  • Front-end Ports: 48
  • Weight: Control enclosure: 38.5; JBOD: 23.8; JBOF: 23
  • Operating Temperature: At -60 m to +900 m: 5°C to 35°C. At 900 m to 3,000 m: reduce by 1°C for every 300 m of elevation gain
  • Storage Temperature: -40°C to 70°C (BBU excluded from the system); 0°C to 70°C recommended
  • Humidity: 10% to 90% RH, non-condensing
  • Storage Humidity: 10% to 93% RH, non-condensing
  • Product Code: HF8000G6-CGF (V6)

When to choose this storage system

Choose it for enterprise enterprise storage system workloads..

Reading the specifications

capacity and controller count set the usable scale and performance headroom; cache (with battery/flash protection) buffers write bursts and random I/O.

Platform & compatibility

Supplied as a complete storage system. Confirm the host protocols, capacity and controller configuration for your environment before ordering.

Deployment notes

The Inspur HF8000G6 High-End Storage is supplied as a configured system; capacity, controllers and licensing are selected at order time. power: AC: 220 V, or 110 V dual live wire (220–264 V); DC: 240 V (240–320 V). Availability, firmware and licensing are confirmed against the current release at order time. Send the required capacity, protocol and performance target for a firm configuration and quote.

FAQ

What cache does it have? 256 GB/512 GB/1 TB/1.5 TB.

How do I get pricing? Send the required capacity and topology; quotes depend on quantity, options and destination.