| Product SKU | HF18000G5 |
|---|---|
| Processor | Multiple multi-core CPUs |
| Storage | SAS SSD, NVMe SSD, SAS HDD, NL-SAS HDD; SAS SSD, NVMe SSD, SAS HDD |
| Storage Controller | RAID 0/1/10/5/6, InRAID 5/6, InRAID 5/6/3C |
| Power Supply | 4U control enclosure: 2,000 W; 2U JBOD: 750 W/850 W; 2U25 JBOF: 850 W; 3U JBOD: 1,100 W/1,200 W; 4U control enclosure: 2,000 W; 2U EBOF: 2,000 W; 3U JBOD: 1,200 W; 2U JBOD and shared JBOD: 850 W |
| Hot-Swap Modules | Controllers, drives, power supplies, fans, BBU, FC cards, NVMe cards, RoCE cards, SAS cards, etc. |
| Security | Intelligent service assurance (InQoS), intelligent automatic cache partitioning (InAutoPartition), intelligent cache acceleration (InFlashCache) |
| Cache | 256 GB/512 GB/1 TB/1.5 TB |
| Disk Enclosure | 2U12-bay / 2U25-bay / 3U48-bay JBOD; 2U25-bay JBOF; mixed use supported. 2U12/2U25/3U48 JBOD; 2U25 shared JBOD; 2U25 EBOF; mixed use supported |
| Front-end Ports | 48 |
| Weight | Control enclosure: 38.5; 2U12 JBOD: 28.8; 2U25 JBOD: 23.8; 3U48 JBOD: 44; 2U25 JBOF: 23; 4U control enclosure: 38.5; 3U48 JBOD: 44; 2U25 JBOD and shared JBOD: 23.8; 2U12 JBOD: 28.8; 2U25 EBOF: 37.7 |
| Operating Temperature | At -60 m to +1,800 m: 0°C to 35°C. At 1,800 m to 3,000 m: reduce by 1°C per 220 m. At 0 m to +900 m: 5°C to 35°C. At 900 m to 3,048 m: reduce by 1°C per 300 m |
| Storage Temperature | -40°C to 70°C (BBU excluded); 0°C to 70°C recommended; also -40°C to 70°C (BBU and HDD excluded); 0°C to 70°C recommended |
| Humidity | 10% to 90% RH, non-condensing |
| Storage Humidity | 5% to 95% RH, non-condensing; 10% to 93% RH, non-condensing |
| Product Code | AS18000G5 |
Storage
Inspur HF18000G5 High-End Storage
The Inspur HF18000G5 is a high-end enterprise storage system.
Overview
The Inspur HF18000G5 is a high-end enterprise storage system. It is configured with multiple multi-core CPUs.
Key Features
- Processor: Multiple multi-core CPUs
- Storage: SAS SSD, NVMe SSD, SAS HDD, NL-SAS HDD; SAS SSD, NVMe SSD, SAS HDD
- Storage Controller: RAID 0/1/10/5/6, InRAID 5/6, InRAID 5/6/3C
- Power Supply: 4U control enclosure: 2,000 W; 2U JBOD: 750 W/850 W; 2U25 JBOF: 850 W; 3U JBOD: 1,100 W/1,200 W; 4U control enclosure: 2,000 W; 2U EBOF: 2,000 W; 3U JBOD: 1,200 W; 2U JBOD and shared JBOD: 850 W
- Security: Intelligent service assurance (InQoS), intelligent automatic cache partitioning (InAutoPartition), intelligent cache acceleration (InFlashCache)
- Weight: Control enclosure: 38.5; 2U12 JBOD: 28.8; 2U25 JBOD: 23.8; 3U48 JBOD: 44; 2U25 JBOF: 23; 4U control enclosure: 38.5; 3U48 JBOD: 44; 2U25 JBOD and shared JBOD: 23.8; 2U12 JBOD: 28.8; 2U25 EBOF: 37.7
- Operating Temperature: At -60 m to +1,800 m: 0°C to 35°C. At 1,800 m to 3,000 m: reduce by 1°C per 220 m. At 0 m to +900 m: 5°C to 35°C. At 900 m to 3,048 m: reduce by 1°C per 300 m
Configuration, availability and lead time depend on the required quantity, system pairing and delivery destination. Send your requirement to receive a quotation.